part of the burette, in order to remove all trace of carbon dioxide. In the meantime the upper part of the apparatus had been completely evacuated. The connection C to the pump was closed, and the hydrogen and emanation were allowed to enter the apparatus, passing over a phosphorous pentoxide tube D. The emanation was condensed in the lower part of the capillary tube A, by surrounding it with the tube B filled with liquid air. The process of condensation was rendered manifest by the brilliant luminosity of the lower part of the tube. The mercury from the burette was then allowed to run to G, and the apparatus again completely evacuated. The connection of the pump was again closed, the liquid air was removed and the volatilized emanation forced into the fine capillary tube A. Observations were then made, from day to day, of the volume of the emanation. The results are given in the table below.
| Time | Volume | Time | Volume |
|---|---|---|---|
| Start | 0·124 cub. mm. | 7 days | 0·0050 cub. mm. |
| 1 day | 0·027 „ | 9 „ | 0·0041 „ |
| 3 „ | 0·011 „ | 11 „ | 0·0020 „ |
| 4 „ | 0·0095 „ | 12 „ | 0·0011 „ |
| 6 „ | 0·0063 „ | 28 „ | 0·0004 „ |
The volume contracted with the time, and was very small after a month’s interval, but the minute bubble of the emanation still retained its luminosity to the last. The tube became deep purple in colour, which rendered readings difficult except with a strong light. There was a sudden decrease in the first day, which may have been due to the mercury sticking in the capillary tube.
The experiments were repeated with another capillary tube and the volume of gas observed at normal pressure was 0·0254 c. mm. The gas obtained was found to obey Boyle’s law within the limit of experimental error over a considerable range of pressure. But, unlike in the first experiment, the gas did not contract but expanded rapidly during the first few hours, and then more slowly, finally reaching a volume after 23 days of 0·262 c. mm. or about 10 times the initial volume. The measurements were complicated by the appearance of bubbles of gas in the top of the mercury column. The differences observed in these two experiments are difficult to account for. We shall see, later, that the emanation always produces helium, and, in the first experiment, the decrease of the volume to zero indicates that the helium was buried or absorbed in the walls of the tube. In the second case, probably owing to some difference in the glass of the capillary tube, the helium may have been released. This suggestion is confirmed by the observation that the volume of gas, after the experiment ended, gave a brilliant spectrum of helium.
We shall see later that there is considerable evidence that the α particles expelled from radio-active substances consist of helium atoms. Since the particles are projected with great velocity, they will first be buried in the walls of the tube, and then may gradually diffuse out into the gas